EI-R105 α、β Surface Contamination Monitor
Home » Products » Radiation Monitor Equipment » EI-R105 α、β Surface Contamination Monitor

Product Category

EI-R105 α、β Surface Contamination Monitor EI-R105 α、β Surface Contamination Monitor

loading

EI-R105 α、β Surface Contamination Monitor

Share to:
sharethis sharing button
  • EI-R105

  • Eastimage

  • EI-R105

Availability:
Quantity:

Product Instruction

EI-R105 is a cloud-based portable surface contamination monitoring device with a ZnS coated plastic scintillator probe with a sensitive detection area of 170cm2 , designed to detect alpha and beta contamination on surfaces or wiped test samples. The instrument has a built-in WIFI and 4G module for field data transmission. The color HD touchscreen display makes it easy to operate and carry. A cloud server can be set up so that measurement data can be automatically uploaded to the cloud server via wireless and mobile networks,

allowing access to the server and data readings anywhere, anytime, as long as the instrument is connected to the internet.

Functional features

Based on a unique detection method, the lower detection limit of the instrument is not affected by external exposure

Built-in WIFI and 4G modules allow you to upload measurement data to the server for subsequent statistics, analysis and display as required

Built-in industry standard (EJ/T1204) method with automatic evaluation and display of lower detection limits

Simultaneous α and β measurements with switchable units of cps, Bq, Bq/cm2

Large HD touchscreen display with manual or automatic sensor to turn on the backlight

Alarm thresholds are set in two levels

Automatic deduction of the background function

A library of over 30 freely editable nuclides

Extendable with external probe for X/γ dose rate measurements

Technical specifications

Physical properties

Detector type ZnS coated thin film plastic scintillator detector with optional GM tube detector

Single probe incident window area 170cm2

Unit cps, Bq, Bq/cm2

Background deductions Deductive and non-deductive background optional, background measurement time settable

Background count rate α: < 0.1cps, β : < 20cps

Detector efficiency241Am: ≥ 33%, 90Sr/ 90Y: 35%

Repeatability < 10%

Relative inherent error ≤ &plusmn;25%

Measurement time Timed measurement function, time 1s to 999s continuously adjustable

Alarm methods Audible and visual alarm

Nuclide Library Over 30 nuclides with reset and automatic calibration

Data storage More than 1000 measurement data can be stored

Electrical characteristics

Power supply method NiMH rechargeable battery, >25 hours continuous operation Communication methods USB, WiFi, 4G

Mechanical properties

Machine size 139H&times;132W&times;354D(mm) Weight 1.2kg (with battery)

Environmental characteristics

Working environment Temperature: -20 C to 50 C; Humidity: ≤ 90% (30 C, no condensing)