EI-5040 M
Eastimage
EI-5040 M
Availability: | |
---|---|
Quantity: | |
EI-5040 M Channelized Luggage Radiation Monitoring System
EI-5040 Mis a device for radioactive detection of traveling packages, with high sensitivity, wide detection range and short response time. The product can be used in a variety of entrances and exits or passage, such as homeland borders and ports , etc.
Functional features
– 1 x 12.5L large area plastic scintillator detector as standard, optional NaI detector
– Modular design with lead shielding on the non-detecting side
– Distinguishable between naturally occurring radioactive material and special nuclear material
– Continuously adjustable alarm thresholds
– Multi-point deployment and remote operation possible
– Optional 3He neutron detector available.
– Expandable HD video capture system, online nuclide identification module
– Complies with GB/T 24246-2009 standard requirements
Application areas
– Radioactivity monitoring at entrances and exits of nuclear plants, nuclear facilities, nuclear power stations, etc. to prevent the spread of radioactive materials
– Radiological inspection of container vehicles, train cargo at customs gates, airports and cargo yards, etc.
– Monitoring the presence of radioactive material in vehicles for entrances and exits of metal smelters, scrap steel distribution sites, etc.
– Sanitary entrances and exits of CDC health centres, hospitals, etc.
Technical specifications
Physical properties
★Detector type 12.5L plastic scintillator
★Monitoring area Height: 0.1 m~1m; Width: 1m
★Energy range Gamma: 20keV to 3MeV; Neutron: 0.025eV to 14MeV (optional)
★Sensitivity 0.04μSv/h increase, alarm within 1 second (background level of 0.2μSv/h)
★Shielding method 3mm thick lead shielding substrate for non-detecting surfaces
★False alarm rate ≤ 0.1%
Electrical characteristics
★Power supply method AC 220V±10%, 50Hz±10%
Mechanical properties
★Machine size 1486H×930W×400D(mm)
Environmental characteristics
★Operating temperature 0 C to 40 C
★Communication methods RJ45
★Display method 4.3 LCD screen
★Operating humidity ≤ 95% (no condensing)
EI-5040 M Channelized Luggage Radiation Monitoring System
EI-5040 Mis a device for radioactive detection of traveling packages, with high sensitivity, wide detection range and short response time. The product can be used in a variety of entrances and exits or passage, such as homeland borders and ports , etc.
Functional features
– 1 x 12.5L large area plastic scintillator detector as standard, optional NaI detector
– Modular design with lead shielding on the non-detecting side
– Distinguishable between naturally occurring radioactive material and special nuclear material
– Continuously adjustable alarm thresholds
– Multi-point deployment and remote operation possible
– Optional 3He neutron detector available.
– Expandable HD video capture system, online nuclide identification module
– Complies with GB/T 24246-2009 standard requirements
Application areas
– Radioactivity monitoring at entrances and exits of nuclear plants, nuclear facilities, nuclear power stations, etc. to prevent the spread of radioactive materials
– Radiological inspection of container vehicles, train cargo at customs gates, airports and cargo yards, etc.
– Monitoring the presence of radioactive material in vehicles for entrances and exits of metal smelters, scrap steel distribution sites, etc.
– Sanitary entrances and exits of CDC health centres, hospitals, etc.
Technical specifications
Physical properties
★Detector type 12.5L plastic scintillator
★Monitoring area Height: 0.1 m~1m; Width: 1m
★Energy range Gamma: 20keV to 3MeV; Neutron: 0.025eV to 14MeV (optional)
★Sensitivity 0.04μSv/h increase, alarm within 1 second (background level of 0.2μSv/h)
★Shielding method 3mm thick lead shielding substrate for non-detecting surfaces
★False alarm rate ≤ 0.1%
Electrical characteristics
★Power supply method AC 220V±10%, 50Hz±10%
Mechanical properties
★Machine size 1486H×930W×400D(mm)
Environmental characteristics
★Operating temperature 0 C to 40 C
★Communication methods RJ45
★Display method 4.3 LCD screen
★Operating humidity ≤ 95% (no condensing)
Home | Products | About Us | Technology | News | Contact Us | Privacy Policy